STUDIO
Balanced Flue
Instructions for Use,
Installation and Servicing
For use in GB, IE (Great Britain and Eire)
PR0919 Issue 5 (January 2008)
IMPORTANT
Do not attempt to burn rubbish in this appliance. This appliance must only be operated with the glass door secured firmly in
position. The front casing of this appliance will become hot whilst in operation, it is therefore recommended that a suitable
guard should be used for the protection of young children, the elderly or infirm.
These instructions must be left at the property for future reference and when servicing the fire.
The Commissioning Sheet found on page 3 must be completed by the Corgi Installer.
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the
translated instructions and in some cases the appliance will require modification. Contact Gazco for further information.
Page view 0
1 2 3 4 5 6 ... 32 33

Summary of Contents

Page 1 - Installation and Servicing

STUDIOBalanced Flue Instructions for Use,Installation and ServicingFor use in GB, IE (Great Britain and Eire)PR0919 Issue 5 (January 2008)IMPORTANTDo

Page 2 - SERVICING INSTRUCTIONS 22

10INSTALLATION INSTRUCTIONSTECHNICAL SPECIFICATIONSteel Frame DimensionsDimension Studio 1 Studio 2A 1120 1350B 675 675C 646 846D 320 320E 177 177 F 2

Page 3 - IMPORTANT NOTICE

11INSTALLATION INSTRUCTIONSSITE REQUIREMENTSNote: This appliance must only be installed with the flue supplied.You must adhere to the following: 1.1

Page 4 - USER INSTRUCTIONS

12STUDIO 1 BF1AAR1671STUDIO 2 BF1AAR1971 Start of bend to centre line of horizontal flue 170mm. Centre line of vertical flue to end of bend 220mm.2.1

Page 5

13INSTALLATION INSTRUCTIONSSITE REQUIREMENTS1CAR16732.3 TOP FLUE VERTICAL KIT (8524/8524AN) Vertical from the top of the appliance (See Diagram 1C).

Page 6

14INSTALLATION INSTRUCTIONSSITE REQUIREMENTS/INSTALLATION5. APPLIANCE LOCATION5.1 Please note this appliance has been specifically designed for stud

Page 7

15INSTALLATION INSTRUCTIONSINSTALLATION2AR1869access panel2 AR18883. STUD WORK INSTALLATION3.1 Combustible parts of the stud work must be kept beyon

Page 8

16INSTALLATION INSTRUCTIONSINSTALLATION • Fitthesuppliedtopsupportbarintothestudworkatthecorrect height, Diagram 7, because no combusti

Page 9

17INSTALLATION INSTRUCTIONSINSTALLATION13AR19053.3 STUD WORK INSTALLATION METHOD 2 (EDGE) Forthiscool-wallEdgeinstallation,theconvectedheato

Page 10 - INSTALLATION INSTRUCTIONS

18INSTALLATION INSTRUCTIONSINSTALLATION Studio 1 BF17Studio 2 BFStudio 1 & 2 BFAR1671, AR1971, AR1673 TAKE CARE WHEN MARKING OUT FOR THE FLUE AS

Page 11

19INSTALLATION INSTRUCTIONSINSTALLATION4.6 Onlythehorizontalterminalsectioncanbereducedinsize.To find the length: • Measurefromtheouts

Page 12

2COVERING THE FOLLOWING MODEL: STUDIO 1 BALANCED FLUE: STUDIO 2 BALANCED FLUE: 8700BFCHEC 8701BFCHEC

Page 13

20INSTALLATION INSTRUCTIONSINSTALLATION • Offertheframetothefootoftheopening • Slidetheframetotherighttolocatetherighthingepin2

Page 14

21INSTALLATION INSTRUCTIONSINSTALLATION • PresstheON-OFFbuttontolighttheappliance,(upto  30 seconds) • PresstheUPbuttontoincreas

Page 15

22INSTALLATION INSTRUCTIONSCOMMISSIONING7. COMMISSIONING7.1 Complete the Commissioning Checklist at the front of this manual covering: • Fluecheck

Page 16

23IGNITION FUNCTIONAL CHECK 1PILOTWILLNOTLIGHTEnsurethereisnodebrisaroundthepilotassembly, (e.g. soot, etc.) which could short the spark,

Page 17

24PILOTWILLNOTSTAYLITORFIREGOESOUTINUSEEnsurethereisnodebrisaroundthepilotassembly,(e.g. soot etc.) Check for fluff in the pilot ae

Page 18

3.2 To completely remove the glass front: • Removethesecuringspringclipfromthebottom-rightof the window frame, Diagram 33AR18623.3 With

Page 19

26SERVICING INSTRUCTIONSREPLACING PARTS 4. GLASS WINDOW4.1 Remove the two clips and brackets from either side of the frame, Diagram 55AR1864 • Lift

Page 20

279AR1868 • Slidetheburnertotherightandoutofitslocation • Refitinreverseorder Whenrefillingthestonepebbles,filltothelevelof

Page 21

28SERVICING INSTRUCTIONSREPLACING PARTS8. PILOT UNIT ASSEMBLY8.1 The pilot assembly consists of four components which can be individually changed: 1

Page 22

29SERVICING INSTRUCTIONSREPLACING PARTS10. GAS VALVE10.1 To change the gas valve: • Removethecontrolassembly,Section7 • Releasethegasinl

Page 23 - SERVICING INSTRUCTIONS

3FLUE CHECK PASS FAIL1. Flue is correct for appliance 2. Flue flow test N/A 3. Spillage test N/A GAS CHECK 1. Gas soundness & let by test2.

Page 24

30SERVICING INSTRUCTIONSREPLACING PARTS13. MAIN INJECTOR13.1 To change the main injector: • Undotheinjectorfeepipe • Undothelocknutfromt

Page 25

31SERVICING INSTRUCTIONSREPLACING PARTS15. SHORT SPARES LISTSTUDIO 1 BF STUDIO 2 BFCOMPONENT NG LPG NG LPGPILOTINJECTOR PI0069 PI0070 PI0069 PI00

Page 26

32SERVICE RECORDS1ST SERVICEDate of Service:...Next Service Due:...

Page 27

Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JGTel: (01392) 261999 Fax: (01392) 444148 E-mail: [email protected]

Page 28

4USER INSTRUCTIONS 1. GENERAL1.1 A competent person must carry out installation and servicing.1.2 In all correspondence, please quote the appliance

Page 29

5USER INSTRUCTIONS DECREASINGTEMPERATURE • PresstheDOWNarrowoncetodecreaseflameheight  one stage  • PressandholdtheDOWNarrowto

Page 30

6USER INSTRUCTIONS • PresstheON-OFFbuttontoturntheapplianceoffEMERGENCY SHUT OFF If the batteries fail during use of the fire, move the swi

Page 31

7USER INSTRUCTIONS5. ARRANGEMENT OF FUEL BED5.1 If you need to replace pebbles or refill the tray, make sure the pebbles are flattened so they are le

Page 32 - SERVICE RECORDS

8Model Gas CAT.Gas TypeWorkingPressureAeration Injector Gas Ratem3/hInput kW (Gross) CountryHigh LowStudio 1 BF 12H Natural G2020mbar 16 x 23 400 0.60

Page 33 - A member of the Stovax Group

9INSTALLATION INSTRUCTIONSTECHNICAL SPECIFICATIONThis appliance has been certified for use in countries other than those stated. To install this appli