Clarendon & AshdonLog Effect Stove RangeBalanced FlueWith upgradeable control valveInstructions for Use,Installation and ServicingFor use in GB, I
101.2 REAR FLUE 8526Terminal dimensions:395 x 200 x 200 mm (H x W x D)Cut to length as required on site.Guard Supplied.1.3 TOP EXITTwo types of top
111.5 TOP FLUE UP & OUT WITH ADDITIONALBENDAny additional bend may be used on the horizontal section(either 45° or 90°) but the overall horizontal
122. VENTILATIONThe appliance requires no additional ventilation.3. INSTALLATION OF THE GAS SUPPLY3.1 Before installation, ensure that the local dist
13IMPORTANT: ENSURE THAT THE APPLIANCE ISCORRECTLY ADJUSTED FOR THE GAS TYPE ANDCATEGORY APPLICABLE IN THE COUNTRY OF USE.REFER TO DATABADGE AND TECHN
143.1.5 To set the flue length, measure the total wall thickness, thenadd 65mm. This total flue length will give the minimumclearance of 50mm between
15INSTALLATION INSTRUCTIONSINSTALLATION3.2 TOP EXIT 3.2.1 There are two types of top exit flues available, one with avertical terminal, the other with
3.3 TOP EXIT - VERTICAL FLUE3.3.1 If a vertical only flue system has been purchased refer toSite Requirements, Diagram 5.The following areas need care
17INSTALLATION INSTRUCTIONSINSTALLATION5. FUELBED ARRANGEMENTSRemove the cast iron door using the tool provided. Themain ceramic components are inside
5.4 Place the second ash panel to the right of the first, with thepointed end of the panel fitting into the V shape. This panelshould locate on the sc
1. COMMISSIONING1.1 Having run the gas supply to the stove, PURGE THE SUPPLYPIPE, this is essential to expel any debris that may block thegas control
2CONTENTSCOVERING THE FOLLOWING MODELSASHDON - 8546LUC - P8546LUC / 8544LUC - P8544LUCCLARENDON 8545LUC - P8545LUC / 8547LUC - P8547LUCPAGEAPPLIANCE C
201. SERVICING REQUIREMENTSThis appliance must be serviced at least once a year by acompetent person.All tests must be serviced by best practice as de
21SERVICING INSTRUCTIONSSERVICING / FAULT FINDING CHARTSNO SPARKIGNITION FUNCTIONAL CHECK 2Ensure there is no debris around the pilot assembly, (e.g.
22SERVICING INSTRUCTIONSREPLACING PARTS1. GENERAL1.1 All principal components can be replaced without removingthe stove from its installation, althou
23SERVICING INSTRUCTIONSREPLACING PARTS3.4 To remove the pilot injector, undo the compression nut onthe pilot feed pipe and withdraw the injector whi
24SERVICING INSTRUCTIONSREPLACING PARTS4.3 To release the right hand side of the control cover insert thenarrow blade screwdriver into the slot shown
25SERVICING INSTRUCTIONSREPLACING PARTS8.4 Holding the injector with a spanner, undo the feed pipe.NOTE: THE ORIENTATION OF THE INJECTOR.8.5 Reassem
26SERVICE RECORDS1ST SERVICEDate of Service:...Next Service Due:...
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JGTel: (01392) 261999 Fax: (01392) 444148 E-mail: [email protected]
3FLUE CHECK PASS FAIL1. Flue is correct for appliance2. Flue flow test N/A3. Spillage test N/AGAS CHECK1. Gas soundness & let by test2. Standing p
4USER INSTRUCTIONS1. GENERAL1.1 Installation and servicing must be carried out by acompetent person.1.2 In all correspondence, please quote the appl
7.2 Place log B on the left hand side of the burner with thelocation bar on the underside of the log fully located in thelong slot of the burner. Make
67.4 Place log D across from the rear log A to log B on the left-hand side. There are cut-outs in both logs for location. Seediagram 5.7.5 There are
8. THE FLAME FAILURE DEVICE8.1 This is a safety feature incorporated in all GAZCO fireswhich automatically switches off the gas supply if the pilotli
8INSTALLATION INSTRUCTIONSTECHNICAL SPECIFICATIONCOVERING THE FOLLOWING MODELS:ASHDON - 8546LUC - P8546LUC / 8544LUC - P8544LUCCLARENDON - 8545LUC - P
9INSTALLATION INSTRUCTIONSSITE REQUIREMENTS1. FLUE AND CHIMNEY REQUIREMENTSNOTE: This appliance can only be installed in conjunctionwith the flue supp