Stockton 8Integral Boiler StoveMODEL: 7129Installation and Operating InstructionsFor Use in Great Britain and EireIMPORTANTPlease read these instructi
10OPERATING INSTRUCTIONSCaution!Parts of the Stockton stove are manufactured from cast iron, which needs to be temperedbefore the stove is operated at
11OPERATING INSTRUCTIONSSolid Fuel1.1 Using solid fuel.1.2 Open the Airwash air control to approximately 50% open and Primary air controlfully. See di
12OPERATING INSTRUCTIONS1.4 As the fire becomes established add larger pieces of wood and close the Primary aircontroland control the burn rate using
13OPERATING INSTRUCTIONS3. ASH REMOVAL3.1 The burning of any fuel will produce ash, which will have to be removed after a periodof use. This time will
14MAINTENANCE1.GENERAL CLEANING1.1 We would recommend that your Stockton stove be cleaned fully on a regular basis,according to the level of use. Atte
15MAINTENANCE4.4 Clean the internal surfaces of the appliance using a wire brush and scraper as required.Vacuum and brush the resulting debris from th
16MAINTENANCE5. RECOMMENDED FUELSWood:- Burn only seasoned timber, with a moisture content of less than 20%. In most cases this would require drying c
MAINTENANCE6. STOVAX STOVECARE PRODUCTSThe following products, all available from your local Stovax stove stockist, will help you tokeep your stove in
19
2FOR YOUR RECORDSTo assist us in any Guarantee claim please complete the following information:-Stovax dealer appliance was purchased fromName: ...
Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LFTel: (01392) 474011 Fax: (01392) 219932 E-mail: [email protected]
3PRE-INSTALLATION CHECKSBefore installation of this product please read these instructions fully.It is very important to also understand the requireme
4PRE-INSTALLATION CHECKSCheck that the Flue or Chimney is structurally sound. In particular, it should not be possiblefor products of combustion to co
5INSTALLATION3. HEATING CIRCUITAll water heating installations should be designed, before product installation, and installed bya competent heating en
6INSTALLATIONHot waterAn allowance should be made in any calculation for the heat requirement for any hot watertank fitted to the system.Pipe lossesCo
7INSTALLATIONBecause each installation is unique to the property, it is not possible to give full details of theconstructional hearth setting. Howeve
8INSTALLATION2.7 The system vent should be a minimum diameter of 22mm and fitted with an airseparation device.2.8 The Heat Sink (Slumber circuit) must
9INSTALLATION3. COMMISSIONING3.1 Check there are no leaks in the water system and all internal parts are correctly fitted,all seals are undamaged and