VFC Radiant & ConvectorFire RangeWith upgradeable control valveInstructions for Use,Installation and ServicingFor use in GB, IE (Great Britain and
104.4 The appliance must be firmly fixed to the hearth. Fasteners areprovided for this purpose.4.5 Ensure that no naked flame or incandescent part of
4. INSTALLATION - RADIANT FIRES4.1 Fix the rear leg strap. See diagram 1.4.2 Position the fire with the rear leg fully engaged under the rearleg stra
124.8 Fit the fret to the fire front using two screws. See diagram 4.5. INSTALLATION - CONVECTOR FIRES5.1 Make any necessary alterations to fireplace
Protective clothing is not required when handling these articles,but we recommend you follow normal hygiene rules of notsmoking, eating or drinking in
146.5 Flat fronts (All others) - Place 3 large coals and 4 small coals onto the front coal moulding ensuring that they rest against thedecorative fron
155.13 Place the remaining 5 small coals on top of the others so thatthey form a bridge between the second and third rows. Seediagram 23.22” COAL LAYO
161. COMMISSIONING1.1 Close all windows and doors to the room, check all controls, and allow fire to burn on maximum for 5 minutes. Test forspillage o
17This appliance must be serviced at least one a year by acompetent person.1. SERVICING REQUIREMENTS1.1 As part of the annual service, the space behin
18FAULT FINDINGIGNITION FUNCTIONAL CHECK 1PILOT WILL NOT LIGHTEnsure there is no debris around the pilot assembly, e.g coal, soot, etc whichcould shor
19INSTALLATION INSTRUCTIONSREPLACING PARTS2. IGNITION LEADThe following part can be serviced without removing thefire.2.1 Turn off the gas supply at t
2CONTENTSPAGECommissioning Check List 3USER INSTRUCTIONS 4INSTALLATION INSTRUCTIONSTechnical Specifications 8Site Requirements 9Installation 11Commiss
205. ODS PILOT UNITNote: The pilot unit on the appliance is a non serviceable unit dueto the complex nature of its manufacture. Replacement of thecomp
216.5 Disconnect the ignition lead from the gas valve, refer to section 27.6.6 Undo the two bolts securing the gas valve to the appliance andremove th
MANUAL FIRES RD 16 18 22CERAMIC PARTSFront Coal LH CE0151 CE0152 CEO153/54Flame Baffle CE0119 CE0120 CEO121Burner Skin CE0155 CE0156 CEO157Coal Set CE
23SERVICE RECORDS1ST SERVICEDate of Service:...Next Service Due:...
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JGTel: (01392) 261999 Fax: (01392) 444148 E-mail: [email protected]
3FLUE CHECK PASS FAIL1. Flue is correct for appliance2. Flue flow test3. Spillage testGAS CHECK1. Gas soundness & let by test2. Standing pressure
4USER INSTRUCTIONS1.1 Installation and servicing must only be carried out by a competent person.1.2 In your own interest, and those of safety, this ap
7.2 Position the front coal, make sure it sits flat onto the burner skin. See diagram 3 arrow C.7.3 Place the coals following the appropriate diagrams
7.11 Place 6 large coals onto the flame baffle fingers. See diagram 11.7.12 Place 5 large coals so that they form a bridge between the other 2 rows, a
7USER INSTRUCTIONS22” COAL LAYOUT7.14 All fronts - place 8 large coals onto the front coal moulding ensuring that they rest against the front, place 2
8TECHNICAL SPECIFICATIONTHESE INSTRUCTIONS COVER THE FOLLOWING MODELS:VFC RADIANT VFC COVECTOR VFC LOW CONVECTOR8300UC 16” 8420UC 16” 8461UC 16”LLP830
9The flue must be installed in accordance with all local andnational regulation and the current rules in force.1.FLUE AND CHIMNEY REQUIREMENTS1.1 The